About the article

MAGNETIC FLUID SEALING OF AN ELECTRIC MOTOR SHAFT, ADJUSTABLE IN TERMS OF MAINTAINED PRESSURE DIFFERENTIAL, FRICTION LOSSES, ROTATION FREQUENCY AND THERMAL MODE

DOI: 10.46573/2658-5030-2026-1-15-25

Download article

Authors

A.M. VLASOV, Yu.B. KAZAKOV

Abstract

The efficiency of magnetic fluid shaft sealing is affected by the pressure difference and external temperature, conditions and operating mode of the electric motor (start, braking, stopping, reversing, rotation speed and electrical load). Electromagnetic processes in an electric motor, through the action of the rotating magnetic flux of the windings, affect the flow rate of the magnetic fluid, the torque and friction losses in the magnetic fluid seal. It is advisable to regulate the properties of the magnetic fluid shaft seal according to the operating conditions of the electric motor. A design of an adjustable magnetic fluid seal is proposed and an algorithm for its regulation is developed, which allows for the adaptation of the magnetic fluid seal of the shaft to changes in the operating conditions of the electric motor. The possibility of changing the maximum retained pressure difference in an adjustable magnetic fluid seal has been experimentally confirmed.

Keywords

magnetic fluid shaft sealing, electric motor, regulation, pressure drop, friction losses, thermal conditions, rotation speed.