About the article
D.A. BARCHUKOV, E.V. BARABANOVA, L.E. AFANASIEVA, I.A. SMOLYAKOVA
The results of microhardness studies using indentation and scratching with a tetrahedral diamond pyramid using a domestic PMT-3 microhardness tester are presented. Scratching of the steel surface was performed with the indenter oriented edge-first and face-first. An atomic force microscope was used to record and analyze the experimental results. The possibilities and prospects of using atomic force microscopy methods in solving sclerometry problems are shown.
microhardness, sclerometry, testing, diagnostics, atomic force microscopy.